TaInd
SCPI Command :
[SOURce<HW>]:BB:EUTRa:UL:UE<ST>:SL:SCI<CH0>:TAINd
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(userEquipment=UserEquipment.Default, indexNull=IndexNull.Default) int[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:SL:SCI<CH0>:TAINd value: int = driver.source.bb.eutra.uplink.ue.sl.sci.taInd.get(userEquipment = repcap.UserEquipment.Default, indexNull = repcap.IndexNull.Default)
Sets the 11-bits timing advance indicator.
- Parameters:
userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)
indexNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Sci’)
- Returns:
timing_advance_in: integer Range: 0 to 2047
- set(timing_advance_in: int, userEquipment=UserEquipment.Default, indexNull=IndexNull.Default) None[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:SL:SCI<CH0>:TAINd driver.source.bb.eutra.uplink.ue.sl.sci.taInd.set(timing_advance_in = 1, userEquipment = repcap.UserEquipment.Default, indexNull = repcap.IndexNull.Default)
Sets the 11-bits timing advance indicator.
- Parameters:
timing_advance_in – integer Range: 0 to 2047
userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)
indexNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Sci’)