Sindex
SCPI Command :
[SOURce<HW>]:BB:EUTRa:UL:UE<ST>:PRACh:ATT<CH0>:EMTC:SINDex
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(userEquipment=UserEquipment.Default, attenuationNull=AttenuationNull.Default) int[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:PRACh:ATT<CH0>:EMTC:SINDex value: int = driver.source.bb.eutra.uplink.ue.prach.att.emtc.sindex.get(userEquipment = repcap.UserEquipment.Default, attenuationNull = repcap.AttenuationNull.Default)
Sets the sequence index v.
- Parameters:
userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)
attenuationNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Att’)
- Returns:
sequence_index: integer Range: 0 to 63
- set(sequence_index: int, userEquipment=UserEquipment.Default, attenuationNull=AttenuationNull.Default) None[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:PRACh:ATT<CH0>:EMTC:SINDex driver.source.bb.eutra.uplink.ue.prach.att.emtc.sindex.set(sequence_index = 1, userEquipment = repcap.UserEquipment.Default, attenuationNull = repcap.AttenuationNull.Default)
Sets the sequence index v.
- Parameters:
sequence_index – integer Range: 0 to 63
userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)
attenuationNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Att’)