NrUnits

SCPI Command :

[SOURce<HW>]:BB:EUTRa:UL:UE<ST>:NIOT:TRANs<CH>:NRUNits
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(userEquipment=UserEquipment.Default, transmission=Transmission.Default) EutraIotRu[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:NIOT:TRANs<CH>:NRUNits
value: enums.EutraIotRu = driver.source.bb.eutra.uplink.ue.niot.trans.nrUnits.get(userEquipment = repcap.UserEquipment.Default, transmission = repcap.Transmission.Default)

Sets the number of allocated resource units.

Parameters:
  • userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)

  • transmission – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trans’)

Returns:

resource_units: RU1 | RU2 | RU3 | RU4 | RU5 | RU6 | RU8 | RU10

set(resource_units: EutraIotRu, userEquipment=UserEquipment.Default, transmission=Transmission.Default) None[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:NIOT:TRANs<CH>:NRUNits
driver.source.bb.eutra.uplink.ue.niot.trans.nrUnits.set(resource_units = enums.EutraIotRu.RU1, userEquipment = repcap.UserEquipment.Default, transmission = repcap.Transmission.Default)

Sets the number of allocated resource units.

Parameters:
  • resource_units – RU1 | RU2 | RU3 | RU4 | RU5 | RU6 | RU8 | RU10

  • userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)

  • transmission – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trans’)