CycShift
SCPI Command :
[SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(userEquipment=UserEquipment.Default, cellNull=CellNull.Default) int[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift value: int = driver.source.bb.eutra.uplink.ue.cell.refsig.srs.cycShift.get(userEquipment = repcap.UserEquipment.Default, cellNull = repcap.CellNull.Default)
Sets the cyclic shift used for the generation of the sounding reference signal CAZAC sequence.
- Parameters:
userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)
cellNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- Returns:
cyclic_shift: integer Range: 0 to 11 CyclicShift = 7 to 11 if [:SOURcehw]:BB:EUTRa:UL:UEst[:CELLccidx]:REFSig:SRS[srsidx]:NKTC 4
- set(cyclic_shift: int, userEquipment=UserEquipment.Default, cellNull=CellNull.Default) None[source]
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift driver.source.bb.eutra.uplink.ue.cell.refsig.srs.cycShift.set(cyclic_shift = 1, userEquipment = repcap.UserEquipment.Default, cellNull = repcap.CellNull.Default)
Sets the cyclic shift used for the generation of the sounding reference signal CAZAC sequence.
- Parameters:
cyclic_shift – integer Range: 0 to 11 CyclicShift = 7 to 11 if [:SOURcehw]:BB:EUTRa:UL:UEst[:CELLccidx]:REFSig:SRS[srsidx]:NKTC 4
userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)
cellNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)