CycShift#

SCPI Command :

[SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get ( userEquipment=UserEquipment.Default, cellNull=CellNull.Default ) → int
set ( cyclic_shift: int, userEquipment=UserEquipment.Default, cellNull=CellNull.Default ) → None
# [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift
# get:
value: int = driver.source.bb.eutra.uplink.ue.cell.refsig.srs.cycShift.get(userEquipment = repcap.UserEquipment.Default, cellNull = repcap.CellNull.Default)
# set:
driver.source.bb.eutra.uplink.ue.cell.refsig.srs.cycShift.set(cyclic_shift = 1, userEquipment = repcap.UserEquipment.Default, cellNull = repcap.CellNull.Default)

Sets the cyclic shift used for the generation of the sounding reference signal CAZAC sequence.

Parameters:
  • cyclic_shift – integer

  • userEquipment – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)

  • cellNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)