Test:Bb:Generator#
SCPI Commands
- TEST:BB:GENerator:ARBitrary
- TEST:BB:GENerator:SOURce
- TEST:BB:GENerator:STATe
Cloning the Group
// Create a clone of the original group, that exists independently
var generator2 = driver.Test.Bb.Generator.Clone();
Direct SCPI Members
- string Arbitrary#
// SCPI: TEST:BB:GENerator:ARBitrary string value = driver.Test.Bb.Generator.Arbitrary; driver.Test.Bb.Generator.Arbitrary = "abc";Selects the ARB waveform to be tested.
filename: string
- TestBbGenIqSourEnum Source#
// SCPI: TEST:BB:GENerator:SOURce TestBbGenIqSourEnum value = driver.Test.Bb.Generator.Source; driver.Test.Bb.Generator.Source = TestBbGenIqSourEnum.ARB;Selects the test signal source.
iqSource: SINE | CONStant | ARB | TTONe
SINE: Generates a sine waveform. To determine the frequency, use command :TEST:BB:GENerator:FREQuencych.
CONStant: Uses a constant I/Q test signal.
ARB: Selects a signal generated generated by the ARB.
- bool State#
// SCPI: TEST:BB:GENerator:STATe bool value = driver.Test.Bb.Generator.State; driver.Test.Bb.Generator.State = false;Starts the test generator.
state: 1 | ON | 0| OFF
Subgroups