System#

SCPI Commands

SYSTem:CRASh
SYSTem:DID
SYSTem:DLOCk
SYSTem:IMPort
SYSTem:IRESponse
SYSTem:KLOCk
SYSTem:LANGuage
SYSTem:NINFormation
SYSTem:ORESponse
SYSTem:OSYStem
SYSTem:PRESet
SYSTem:PRESet:ALL
SYSTem:PRESet:BASE
SYSTem:RCL
SYSTem:RESet
SYSTem:RESet:ALL
SYSTem:RESet:BASE
SYSTem:SAV
SYSTem:SIMulation
SYSTem:SRCat
SYSTem:SREStore
SYSTem:SRMode
SYSTem:SRSel
SYSTem:SSAVe
SYSTem:TZONe
SYSTem:UPTime
SYSTem:VERSion
SYSTem:WAIT

Cloning the Group

// Create a clone of the original group, that exists independently
var system2 = driver.System.Clone();

Direct SCPI Members

double Crash#
// SCPI: SYSTem:CRASh

driver.System.Crash = 1.0;

No help available.


string Did#
// SCPI: SYSTem:DID
string value = driver.System.Did;

No help available.


bool Dlock#
// SCPI: SYSTem:DLOCk
bool value = driver.System.Dlock;
driver.System.Dlock = false;

Disables the manual operation over the display, including the front panel keyboard of the instrument.

dispLockStat: 1 | ON | 0| OFF


void Import ( string filename )#
// SCPI: SYSTem:IMPort
driver.System.Import("abc");

No help available.


string Iresponse#
// SCPI: SYSTem:IRESponse
string value = driver.System.Iresponse;
driver.System.Iresponse = "abc";

Defines the user defined identification string for *IDN. Note: While working in an emulation mode, the instrument’s specific command set is disabled, i.e. the SCPI command method RsSmw.System.Iresponse is discarded.

idnResponse: string


bool Klock#
// SCPI: SYSTem:KLOCk
bool value = driver.System.Klock;
driver.System.Klock = false;

Disables the front panel keyboard of the instrument.

state: 1 | ON | 0| OFF


string Language#
// SCPI: SYSTem:LANGuage
string value = driver.System.Language;
driver.System.Language = "abc";

Sets the remote control command set.

language: string


string Ninformation#
// SCPI: SYSTem:NINFormation
string value = driver.System.Ninformation;

Queries the oldest information message (Error History > Level > Info) in the error/event queue.

nextInfo: string


string Oresponse#
// SCPI: SYSTem:ORESponse
string value = driver.System.Oresponse;
driver.System.Oresponse = "abc";

Defines the user defined response string for *OPT. Note: While working in an emulation mode, the instrument’s specific command set is disabled, i.e. the SCPI command method RsSmw.System.Oresponse is discarded.

oresponse: string


string Osystem#
// SCPI: SYSTem:OSYStem
string value = driver.System.Osystem;

Queries the operating system of the instrument.

operSystem: string


void Preset ( string pseudoString )#
// SCPI: SYSTem:PRESet
driver.System.Preset("abc");

Triggers an instrument reset. This command has the same effect as:

  • The PRESET key. However, the command does not close open GUI dialogs like the key does.

  • The *RST command

For an overview of the settings affected by the preset function, see Table “Key parameters affected by preset and factory preset”


void PresetAll ( string pseudoString )#
// SCPI: SYSTem:PRESet:ALL
driver.System.PresetAll("abc");

No help available.


void PresetBase ( string pseudoString )#
// SCPI: SYSTem:PRESet:BASE
driver.System.PresetBase("abc");

No help available.


void Recall ( string pathName )#
// SCPI: SYSTem:RCL
driver.System.Recall("abc");

Selects and uploads a savrcltxt file with previously saved R&S SMW200A settings from the default or a specified directory.

pathName string


void Reset ( string pseudoString )#
// SCPI: SYSTem:RESet
driver.System.Reset("abc");

No help available.


void ResetAll ( string pseudoString )#
// SCPI: SYSTem:RESet:ALL
driver.System.ResetAll("abc");

No help available.


void ResetBase ( string pseudoString )#
// SCPI: SYSTem:RESet:BASE
driver.System.ResetBase("abc");

No help available.


void Save ( string pathName )#
// SCPI: SYSTem:SAV
driver.System.Save("abc");

Saves the current R&S SMW200A settings in a file. To deteremine the file name and storage location, enter the directory and file name with the command. According to the file type, the R&S SMW200A assigns the extension (savrcltxt) automatically.

pathName string


bool Simulation#
// SCPI: SYSTem:SIMulation
bool value = driver.System.Simulation;

No help available.


List<string>SrCat#
// SCPI: SYSTem:SRCat
List<string> value = driver.System.SrCat;

No help available.


int Srestore#
// SCPI: SYSTem:SREStore

driver.System.Srestore = 1;

No help available.


RecScpiCmdModeEnum SrMode#
// SCPI: SYSTem:SRMode
RecScpiCmdModeEnum value = driver.System.SrMode;
driver.System.SrMode = RecScpiCmdModeEnum.AUTO;

No help available.


string SrSel#
// SCPI: SYSTem:SRSel
string value = driver.System.SrSel;
driver.System.SrSel = "abc";

No help available.


int Ssave#
// SCPI: SYSTem:SSAVe

driver.System.Ssave = 1;

No help available.


string Tzone#
// SCPI: SYSTem:TZONe
string value = driver.System.Tzone;
driver.System.Tzone = "abc";

No help available.


string UpTime#
// SCPI: SYSTem:UPTime
string value = driver.System.UpTime;

Queries the up time of the operating system.

upTime: “ddd.hh:mm:ss”


string Version#
// SCPI: SYSTem:VERSion
string value = driver.System.Version;

Queries the SCPI version the instrument’s command set complies with.

version: string


int Wait#
// SCPI: SYSTem:WAIT

driver.System.Wait = 1;

Delays the execution of the subsequent remote command by the specified time. This function is useful, for example to execute an SCPI sequence automatically but with a defined time delay between some commands. See “How to assign actions to the USER key”.

TimeMs: Wait time in ms