Source:Sweep:Power#
SCPI Commands
- [SOURce<HW>]:SWEep:POWer:AMODe
- [SOURce<HW>]:SWEep:POWer:DWELl
- [SOURce<HW>]:SWEep:POWer:MODE
- [SOURce<HW>]:SWEep:POWer:POINts
- [SOURce<HW>]:SWEep:POWer:RETRace
- [SOURce<HW>]:SWEep:POWer:RUNNing
- [SOURce<HW>]:SWEep:POWer:SHAPe
Cloning the Group
// Create a clone of the original group, that exists independently
var power2 = driver.Source.Sweep.Power.Clone();
Direct SCPI Members
- PowerAttModeEnum Amode#
// SCPI: [SOURce<HW>]:SWEep:POWer:AMODe PowerAttModeEnum value = driver.Source.Sweep.Power.Amode; driver.Source.Sweep.Power.Amode = PowerAttModeEnum.AUTO;Selects the power attenuator mode for the level sweep.
amode: NORMal | HPOWer
NORMal: Performs the level settings in the range of the built-in attenuator.
HPOWer: Performs the level settings in the high level range.
- double Dwell#
// SCPI: [SOURce<HW>]:SWEep:POWer:DWELl double value = driver.Source.Sweep.Power.Dwell; driver.Source.Sweep.Power.Dwell = 1.0;Sets the dwell time for a level sweep step.
dwell: float
- AutoManStepEnum Mode#
// SCPI: [SOURce<HW>]:SWEep:POWer:MODE AutoManStepEnum value = driver.Source.Sweep.Power.Mode; driver.Source.Sweep.Power.Mode = AutoManStepEnum.AUTO;Sets the cycle mode for the level sweep.
mode: AUTO | MANual | STEP
AUTO: Each trigger triggers exactly one complete sweep.
MANual: The trigger system is not active. You can trigger every step individually with the command [:SOURcehw]:POWer:MANual.The level value increases at each step by the value that you define with [:SOURcehw]:POWer:STEP[:INCRement]. Values directly entered with the command [:SOURcehw]:POWer:MANual are not taken into account.
STEP: Each trigger triggers one sweep step only. The level increases by the value entered with [:SOURcehw]:POWer:STEP[:INCRement].
- int Points#
// SCPI: [SOURce<HW>]:SWEep:POWer:POINts int value = driver.Source.Sweep.Power.Points; driver.Source.Sweep.Power.Points = 1;Sets the number of steps within the RF level sweep range.
points: integer
- bool Retrace#
// SCPI: [SOURce<HW>]:SWEep:POWer:RETRace bool value = driver.Source.Sweep.Power.Retrace; driver.Source.Sweep.Power.Retrace = false;Activates that the signal changes to the start frequency value while it is waiting for the next trigger event. You can enable this feature, when you are working with sawtooth shapes in sweep mode Single or External Single.
state: 1 | ON | 0| OFF
- bool Running#
// SCPI: [SOURce<HW>]:SWEep:POWer:RUNNing bool value = driver.Source.Sweep.Power.Running;Queries the current sweep state.
state: 1 | ON | 0| OFF
- SweCyclModeEnum Shape#
// SCPI: [SOURce<HW>]:SWEep:POWer:SHAPe SweCyclModeEnum value = driver.Source.Sweep.Power.Shape; driver.Source.Sweep.Power.Shape = SweCyclModeEnum.SAWTooth;Determines the waveform shape for a frequency sweep sequence.
shape: SAWTooth | TRIangle
Subgroups