Source:Regenerator:Object:Power:Rx:Dedication#
SCPI Commands
- [SOURce<HW>]:REGenerator:OBJect<CH>:POWer:RX:DEDication
Direct SCPI Members
- RegObjPowDedicStartRangEnum Get ( )#
- RegObjPowDedicStartRangEnum Get ( ObjectIxRepCap objectIx )
- void Set ( RegObjPowDedicStartRangEnum dedication )#
- void Set ( RegObjPowDedicStartRangEnum dedication, ObjectIxRepCap objectIx )
// SCPI: [SOURce<HW>]:REGenerator:OBJect<CH>:POWer:RX:DEDication // Get: RegObjPowDedicStartRangEnum value = driver.Source.Regenerator.Object.Power.Rx.Dedication.Get(); RegObjPowDedicStartRangEnum value = driver.Source.Regenerator.Object.Power.Rx.Dedication.Get(ObjectIxRepCap.Default); // Set: driver.Source.Regenerator.Object.Power.Rx.Dedication.Set(RegObjPowDedicStartRangEnum.ALL, ObjectIxRepCap.Default); driver.Source.Regenerator.Object.Power.Rx.Dedication.Set(RegObjPowDedicStartRangEnum.ALL);
In method RsSmw.Source.Regenerator.Radar.Power.Mode MANual mode and for moving objects, defines how to interpret the value PRX set with the command method RsSmw.Source.Regenerator.Object.Power.Rx.Set.
dedicationSTARt | END | ALLSTARt: PRx, jStartRange = PRX
END: PRx, jEndRange = PRX
ALL: PRx, jStartRange = PRx, jEndRange = PRX
objectIxRepeated capability selectorWhen you do not use any explicit repeated capability selector, the value is taken from its parent group.