Source:Fsimulator:Scm:Tap:SubPath:Phase:Vv#

SCPI Commands

[SOURce<HW>]:FSIMulator:SCM:TAP<ST>:SUBPath<DI>:PHASe:VV

Direct SCPI Members

double Get ( )#
double Get ( MimoTapRepCap mimoTap, SubPathRepCap subPath )
void Set ( double phaseVv )#
void Set ( double phaseVv, MimoTapRepCap mimoTap, SubPathRepCap subPath )
// SCPI: [SOURce<HW>]:FSIMulator:SCM:TAP<ST>:SUBPath<DI>:PHASe:VV
// Get:
double value = driver.Source.Fsimulator.Scm.Tap.SubPath.Phase.Vv.Get();
double value = driver.Source.Fsimulator.Scm.Tap.SubPath.Phase.Vv.Get(MimoTapRepCap.Default, SubPathRepCap.Default);
// Set:
driver.Source.Fsimulator.Scm.Tap.SubPath.Phase.Vv.Set(1.0, MimoTapRepCap.Default, SubPathRepCap.Default);
driver.Source.Fsimulator.Scm.Tap.SubPath.Phase.Vv.Set(1.0);

Sets the start phase in degree of the LOS signal / the subpath per MIMO channel.

phaseVv float

mimoTap Repeated capability selector

subPath Repeated capability selector

When you do not use any explicit repeated capability selector, the value is taken from its parent group.