Source:Fsimulator:Scm:Tap:Arrival:Zenith:Angle#

SCPI Commands

[SOURce<HW>]:FSIMulator:SCM:TAP<ST>:ARRival:ZENith:ANGLe

Direct SCPI Members

double Get ( )#
double Get ( MimoTapRepCap mimoTap )
void Set ( double arrZenith )#
void Set ( double arrZenith, MimoTapRepCap mimoTap )
// SCPI: [SOURce<HW>]:FSIMulator:SCM:TAP<ST>:ARRival:ZENith:ANGLe
// Get:
double value = driver.Source.Fsimulator.Scm.Tap.Arrival.Zenith.Angle.Get();
double value = driver.Source.Fsimulator.Scm.Tap.Arrival.Zenith.Angle.Get(MimoTapRepCap.Default);
// Set:
driver.Source.Fsimulator.Scm.Tap.Arrival.Zenith.Angle.Set(1.0, MimoTapRepCap.Default);
driver.Source.Fsimulator.Scm.Tap.Arrival.Zenith.Angle.Set(1.0);

Sets the AoA (angle of arrival) / AoD (angle of departure) of the cluster.

arrZenith float

mimoTap Repeated capability selector

When you do not use any explicit repeated capability selector, the value is taken from its parent group.