Source:Correction:Optimize:Rf:Linearize#

SCPI Commands

[SOURce<HW>]:CORRection:OPTimize:RF:LINearize:ADJust

Direct SCPI Members

bool Adjust#
// SCPI: [SOURce<HW>]:CORRection:OPTimize:RF:LINearize:ADJust
bool value = driver.Source.Correction.Optimize.Rf.Linearize.Adjust;

Measures the AM/AM nonlinearity on the RF chain for the current frequency. During the measurement, the instrument interrupts signal generation.

adjustResult: 1 | ON | 0| OFF