Sense:Power:Filter:Length:User#
SCPI Commands
- SENSe<CH>:[POWer]:FILTer:LENGth:[USER]
Direct SCPI Members
- double Get ( )#
- double Get ( ChannelRepCap channel )
- void Set ( double user )#
- void Set ( double user, ChannelRepCap channel )
// SCPI: SENSe<CH>:[POWer]:FILTer:LENGth:[USER] // Get: double value = driver.Sense.Power.Filter.Length.User.Get(); double value = driver.Sense.Power.Filter.Length.User.Get(ChannelRepCap.Default); // Set: driver.Sense.Power.Filter.Length.User.Set(1.0, ChannelRepCap.Default); driver.Sense.Power.Filter.Length.User.Set(1.0);
Selects the filter length for SENS:POW:FILT:’TYPE USER. As the filter length works as a multiplier for the time window, a constant filter length results in a constant measurement time (see also “About the measuring principle, averaging filter, filter length, and achieving stable results”) . The R&S NRP power sensors provide different resolutions for setting the filter length, depending on the used sensor type. For more information, refer to the specifications document.
userfloatchannelRepeated capability selectorWhen you do not use any explicit repeated capability selector, the value is taken from its parent group.