Source code for RsFsw.Implementations.System.Security.State

from ....Internal.Core import Core
from ....Internal.CommandsGroup import CommandsGroup
from ....Internal import Conversions


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class StateCls: """State commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("state", core, parent)
[docs] def set(self, state: bool) -> None: """SCPI: SYSTem:SECurity[:STATe] \n Snippet: driver.system.security.state.set(state = False) \n Activates or queries secure user mode. Note: Before you activate secure user mode, store any instrument settings that are required beyond the current session, such as predefined instrument settings, transducer files, or self-alignment data. Note: Initially after installation of the FSW-K33 option, secure user mode must be enabled manually once before remote control is possible. This is necessary to prompt for a change of passwords. For details on the secure user mode see 'Protecting data using the secure user mode'. \n :param state: ON | OFF | 0 | 1 ON | 1 The FSW automatically reboots and starts in secure user mode. In secure user mode, no data is written to the instrument's internal solid-state drive. Data that the FSW normally stores on the solid-state drive is redirected to SDRAM. OFF | 0 The FSW is set to normal instrument mode. Data is stored to the internal solid-state drive. Note: this parameter is for query only. Secure user mode cannot be deactivated via remote operation. """ param = Conversions.bool_to_str(state) self._core.io.write(f'SYSTem:SECurity:STATe {param}')
[docs] def get(self) -> bool: """SCPI: SYSTem:SECurity[:STATe] \n Snippet: value: bool = driver.system.security.state.get() \n Activates or queries secure user mode. Note: Before you activate secure user mode, store any instrument settings that are required beyond the current session, such as predefined instrument settings, transducer files, or self-alignment data. Note: Initially after installation of the FSW-K33 option, secure user mode must be enabled manually once before remote control is possible. This is necessary to prompt for a change of passwords. For details on the secure user mode see 'Protecting data using the secure user mode'. \n :return: state: ON | OFF | 0 | 1 ON | 1 The FSW automatically reboots and starts in secure user mode. In secure user mode, no data is written to the instrument's internal solid-state drive. Data that the FSW normally stores on the solid-state drive is redirected to SDRAM. OFF | 0 The FSW is set to normal instrument mode. Data is stored to the internal solid-state drive. Note: this parameter is for query only. Secure user mode cannot be deactivated via remote operation.""" response = self._core.io.query_str(f'SYSTem:SECurity:STATe?') return Conversions.str_to_bool(response)