[docs]classModeCls:"""Mode commands group definition. 2 total commands, 1 Subgroups, 1 group commands"""def__init__(self,core:Core,parent):self._core=coreself._cmd_group=CommandsGroup("mode",core,parent)@propertydefhcontinuous(self):"""hcontinuous commands group. 0 Sub-classes, 1 commands."""ifnothasattr(self,'_hcontinuous'):from.HcontinuousimportHcontinuousClsself._hcontinuous=HcontinuousCls(self._core,self._cmd_group)returnself._hcontinuous
[docs]defset(self,trace_mode:enums.TraceModeF,window=repcap.Window.Default,subWindow=repcap.SubWindow.Default,trace=repcap.Trace.Default)->None:"""SCPI: DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE \n Snippet: driver.display.window.subwindow.trace.mode.set(trace_mode = enums.TraceModeF.AVERage, window = repcap.Window.Default, subWindow = repcap.SubWindow.Default, trace = repcap.Trace.Default) \n Selects the trace mode. If necessary, the selected trace is also activated. For max hold, min hold or average trace mode, you can set the number of single measurements with [SENSe:]SWEep:COUNt. Note that synchronization to the end of the measurement is possible only in single sweep mode. In the R&S FSW AM/FM/PM Modulation Analysis application, when you configure the traces for a window with a specific evaluation (e.g. AM time domain) , the traces in all windows with the same evaluation are configured identically. For more information, see 'Analyzing Several Traces - Trace Mode'. \n :param trace_mode: WRITe (default:) Overwrite mode: the trace is overwritten by each sweep. AVERage The average is formed over several sweeps. The 'Sweep/Average Count' determines the number of averaging procedures. MAXHold The maximum value is determined over several sweeps and displayed. The FSW saves the sweep result in the trace memory only if the new value is greater than the previous one. MINHold The minimum value is determined from several measurements and displayed. The FSW saves the sweep result in the trace memory only if the new value is lower than the previous one. VIEW The current contents of the trace memory are frozen and displayed. BLANk Hides the selected trace. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window') :param subWindow: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Subwindow') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') """param=Conversions.enum_scalar_to_str(trace_mode,enums.TraceModeF)window_cmd_val=self._cmd_group.get_repcap_cmd_value(window,repcap.Window)subWindow_cmd_val=self._cmd_group.get_repcap_cmd_value(subWindow,repcap.SubWindow)trace_cmd_val=self._cmd_group.get_repcap_cmd_value(trace,repcap.Trace)self._core.io.write(f'DISPlay:WINDow{window_cmd_val}:SUBWindow{subWindow_cmd_val}:TRACe{trace_cmd_val}:MODE {param}')
# noinspection PyTypeChecker
[docs]defget(self,window=repcap.Window.Default,subWindow=repcap.SubWindow.Default,trace=repcap.Trace.Default)->enums.TraceModeF:"""SCPI: DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE \n Snippet: value: enums.TraceModeF = driver.display.window.subwindow.trace.mode.get(window = repcap.Window.Default, subWindow = repcap.SubWindow.Default, trace = repcap.Trace.Default) \n Selects the trace mode. If necessary, the selected trace is also activated. For max hold, min hold or average trace mode, you can set the number of single measurements with [SENSe:]SWEep:COUNt. Note that synchronization to the end of the measurement is possible only in single sweep mode. In the R&S FSW AM/FM/PM Modulation Analysis application, when you configure the traces for a window with a specific evaluation (e.g. AM time domain) , the traces in all windows with the same evaluation are configured identically. For more information, see 'Analyzing Several Traces - Trace Mode'. \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window') :param subWindow: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Subwindow') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') :return: trace_mode: WRITe (default:) Overwrite mode: the trace is overwritten by each sweep. AVERage The average is formed over several sweeps. The 'Sweep/Average Count' determines the number of averaging procedures. MAXHold The maximum value is determined over several sweeps and displayed. The FSW saves the sweep result in the trace memory only if the new value is greater than the previous one. MINHold The minimum value is determined from several measurements and displayed. The FSW saves the sweep result in the trace memory only if the new value is lower than the previous one. VIEW The current contents of the trace memory are frozen and displayed. BLANk Hides the selected trace."""window_cmd_val=self._cmd_group.get_repcap_cmd_value(window,repcap.Window)subWindow_cmd_val=self._cmd_group.get_repcap_cmd_value(subWindow,repcap.SubWindow)trace_cmd_val=self._cmd_group.get_repcap_cmd_value(trace,repcap.Trace)response=self._core.io.query_str(f'DISPlay:WINDow{window_cmd_val}:SUBWindow{subWindow_cmd_val}:TRACe{trace_cmd_val}:MODE?')returnConversions.str_to_scalar_enum(response,enums.TraceModeF)
defclone(self)->'ModeCls':"""Clones the group by creating new object from it and its whole existing subgroups Also copies all the existing default Repeated Capabilities setting, which you can change independently without affecting the original group"""new_group=ModeCls(self._core,self._cmd_group.parent)self._cmd_group.synchronize_repcaps(new_group)returnnew_group