Source code for RsFsw.Implementations.Calculate.Marker.Function.Bpower.Mode

from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import enums
from ...... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class ModeCls: """Mode commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("mode", core, parent)
[docs] def set(self, mode: enums.MarkerMode, window=repcap.Window.Default, marker=repcap.Marker.Default) -> None: """SCPI: CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE \n Snippet: driver.calculate.marker.function.bpower.mode.set(mode = enums.MarkerMode.DENSity, window = repcap.Window.Default, marker = repcap.Marker.Default) \n Selects the way the results for a band power marker are displayed. (Note: relative power results are only availabe for delta markers, see .method RsFsw.Calculate.DeltaMarker.Function.Bpower.Mode.set \n :param mode: POWer Result is displayed as an absolute power. The power unit depends on the method RsFsw.Applications.K91_Wlan.Calculate.Unit.Power.set setting. DENSity Result is displayed as a density in dBm/Hz. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param marker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Marker') """ param = Conversions.enum_scalar_to_str(mode, enums.MarkerMode) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) marker_cmd_val = self._cmd_group.get_repcap_cmd_value(marker, repcap.Marker) self._core.io.write(f'CALCulate{window_cmd_val}:MARKer{marker_cmd_val}:FUNCtion:BPOWer:MODE {param}')
# noinspection PyTypeChecker
[docs] def get(self, window=repcap.Window.Default, marker=repcap.Marker.Default) -> enums.MarkerMode: """SCPI: CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE \n Snippet: value: enums.MarkerMode = driver.calculate.marker.function.bpower.mode.get(window = repcap.Window.Default, marker = repcap.Marker.Default) \n Selects the way the results for a band power marker are displayed. (Note: relative power results are only availabe for delta markers, see .method RsFsw.Calculate.DeltaMarker.Function.Bpower.Mode.set \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param marker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Marker') :return: mode: POWer Result is displayed as an absolute power. The power unit depends on the method RsFsw.Applications.K91_Wlan.Calculate.Unit.Power.set setting. DENSity Result is displayed as a density in dBm/Hz.""" window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) marker_cmd_val = self._cmd_group.get_repcap_cmd_value(marker, repcap.Marker) response = self._core.io.query_str(f'CALCulate{window_cmd_val}:MARKer{marker_cmd_val}:FUNCtion:BPOWer:MODE?') return Conversions.str_to_scalar_enum(response, enums.MarkerMode)