Source code for RsFsw.Implementations.Calculate.Limit.AcPower.State

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal import Conversions
from ..... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class StateCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("state", core, parent)

[docs] def set(self, state: bool, window=repcap.Window.Default, limitIx=repcap.LimitIx.Default) -> None: """ ``CALCulate<n>:LIMit<li>:ACPower[:STATe]`` \n Snippet: ``driver.calculate.limit.acPower.state.set(state = False, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default)`` \n Turns the limit check for ACLR measurements on and off. In addition, limits must be defined and activated individually for each channel (see method ``RsFsw.calculate.limit.acPower.achannel.relative.state.set()`` , method ``RsFsw.calculate.limit.acPower.alternate.relative.state.set()`` , method ``RsFsw.calculate.limit.acPower.gap.auto.absolute.state.set()`` , method ``RsFsw.calculate.limit.acPower.gap.auto.aclr.relative.state.set()`` and method ``RsFsw.calculate.limit.acPower.gap.auto.caclr.relative.state.set()`` ) . :param state: ON | OFF | 1 | 0 :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param limitIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Limit') """ param = Conversions.bool_to_str(state) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) limitIx_cmd_val = self._cmd_group.get_repcap_cmd_value(limitIx, repcap.LimitIx) self._core.io.write(f'CALCulate{window_cmd_val}:LIMit{limitIx_cmd_val}:ACPower:STATe {param}')
[docs] def get(self, window=repcap.Window.Default, limitIx=repcap.LimitIx.Default) -> bool: """ ``CALCulate<n>:LIMit<li>:ACPower[:STATe]`` \n Snippet: ``value: bool = driver.calculate.limit.acPower.state.get(window = repcap.Window.Default, limitIx = repcap.LimitIx.Default)`` \n Turns the limit check for ACLR measurements on and off. In addition, limits must be defined and activated individually for each channel (see method ``RsFsw.calculate.limit.acPower.achannel.relative.state.set()`` , method ``RsFsw.calculate.limit.acPower.alternate.relative.state.set()`` , method ``RsFsw.calculate.limit.acPower.gap.auto.absolute.state.set()`` , method ``RsFsw.calculate.limit.acPower.gap.auto.aclr.relative.state.set()`` and method ``RsFsw.calculate.limit.acPower.gap.auto.caclr.relative.state.set()`` ) . :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param limitIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Limit') :return: state: ON | OFF | 1 | 0 """ window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) limitIx_cmd_val = self._cmd_group.get_repcap_cmd_value(limitIx, repcap.LimitIx) response = self._core.io.query_str(f'CALCulate{window_cmd_val}:LIMit{limitIx_cmd_val}:ACPower:STATe?') return Conversions.str_to_bool(response)