[docs]classXCls:"""X commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""def__init__(self,core:Core,parent):self._core=coreself._cmd_group=CommandsGroup("x",core,parent)
[docs]defset(self,ref_point:float,window=repcap.Window.Default,deltaMarker=repcap.DeltaMarker.Default)->None:"""SCPI: CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X \n Snippet: driver.calculate.deltaMarker.function.fixed.rpoint.x.set(ref_point = 1.0, window = repcap.Window.Default, deltaMarker = repcap.DeltaMarker.Default) \n Defines the horizontal position of the fixed delta marker reference point. The coordinates of the reference may be anywhere in the diagram. \n :param ref_point: Numeric value that defines the horizontal position of the reference. For frequency domain measurements, it is a frequency in Hz. For time domain measurements, it is a point in time in s. Unit: HZ :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param deltaMarker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'DeltaMarker') """param=Conversions.decimal_value_to_str(ref_point)window_cmd_val=self._cmd_group.get_repcap_cmd_value(window,repcap.Window)deltaMarker_cmd_val=self._cmd_group.get_repcap_cmd_value(deltaMarker,repcap.DeltaMarker)self._core.io.write(f'CALCulate{window_cmd_val}:DELTamarker{deltaMarker_cmd_val}:FUNCtion:FIXed:RPOint:X {param}')
[docs]defget(self,window=repcap.Window.Default,deltaMarker=repcap.DeltaMarker.Default)->float:"""SCPI: CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X \n Snippet: value: float = driver.calculate.deltaMarker.function.fixed.rpoint.x.get(window = repcap.Window.Default, deltaMarker = repcap.DeltaMarker.Default) \n Defines the horizontal position of the fixed delta marker reference point. The coordinates of the reference may be anywhere in the diagram. \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param deltaMarker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'DeltaMarker') :return: ref_point: Numeric value that defines the horizontal position of the reference. For frequency domain measurements, it is a frequency in Hz. For time domain measurements, it is a point in time in s. Unit: HZ"""window_cmd_val=self._cmd_group.get_repcap_cmd_value(window,repcap.Window)deltaMarker_cmd_val=self._cmd_group.get_repcap_cmd_value(deltaMarker,repcap.DeltaMarker)response=self._core.io.query_str(f'CALCulate{window_cmd_val}:DELTamarker{deltaMarker_cmd_val}:FUNCtion:FIXed:RPOint:X?')returnConversions.str_to_float(response)