Source code for RsFsw.Implementations.Applications.K91_Wlan.Configure.Burst.Spectrum.Flatness.Select

from ........Internal.Core import Core
from ........Internal.CommandsGroup import CommandsGroup
from ........Internal import Conversions
from ........ import enums


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class SelectCls: """Select commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("select", core, parent)
[docs] def set(self, meas_type: enums.MeasurementTypeK91) -> None: """SCPI: CONFigure:BURSt:SPECtrum:FLATness:SELect \n Snippet: driver.applications.k91Wlan.configure.burst.spectrum.flatness.select.set(meas_type = enums.MeasurementTypeK91.FLATness) \n This remote control command configures result display type of window 2 to be either 'Spectrum Flatness' or 'Group Delay'. Results are only displayed after a measurement is executed, e.g. using the method RsFsw.Applications.K10x_Lte.Initiate. Immediate.set command. Note that the CONF:BURS:<ResultType>:IMM commands change the screen layout to display the 'Magnitude Capture' buffer in window 1 at the top of the screen and the selected result type in window 2 below that. Any other active windows are closed. Use the LAYout commands to change the display (see 'Working with windows in the display') . \n :param meas_type: FLATness | GRDelay """ param = Conversions.enum_scalar_to_str(meas_type, enums.MeasurementTypeK91) self._core.io.write(f'CONFigure:BURSt:SPECtrum:FLATness:SELect {param}')
# noinspection PyTypeChecker
[docs] def get(self) -> enums.MeasurementTypeK91: """SCPI: CONFigure:BURSt:SPECtrum:FLATness:SELect \n Snippet: value: enums.MeasurementTypeK91 = driver.applications.k91Wlan.configure.burst.spectrum.flatness.select.get() \n This remote control command configures result display type of window 2 to be either 'Spectrum Flatness' or 'Group Delay'. Results are only displayed after a measurement is executed, e.g. using the method RsFsw.Applications.K10x_Lte.Initiate. Immediate.set command. Note that the CONF:BURS:<ResultType>:IMM commands change the screen layout to display the 'Magnitude Capture' buffer in window 1 at the top of the screen and the selected result type in window 2 below that. Any other active windows are closed. Use the LAYout commands to change the display (see 'Working with windows in the display') . \n :return: meas_type: FLATness | GRDelay""" response = self._core.io.query_str(f'CONFigure:BURSt:SPECtrum:FLATness:SELect?') return Conversions.str_to_scalar_enum(response, enums.MeasurementTypeK91)