Source code for RsFsw.Implementations.Applications.K70_Vsa.Output.Trigger.Level

from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import enums
from ...... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class LevelCls: """Level commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("level", core, parent)
[docs] def set(self, trigger_output_level: enums.LowHigh, outputConnector=repcap.OutputConnector.Default, triggerPort=repcap.TriggerPort.Default) -> None: """SCPI: OUTPut<up>:TRIGger<tp>:LEVel \n Snippet: driver.applications.k70Vsa.output.trigger.level.set(trigger_output_level = enums.LowHigh.HIGH, outputConnector = repcap.OutputConnector.Default, triggerPort = repcap.TriggerPort.Default) \n Defines the level of the (TTL compatible) signal generated at the trigger output. Works only if you have selected a user-defined output with method RsFsw.Applications.K17_Mcgd.Output.Trigger.Otype.set. \n :param trigger_output_level: No help available :param outputConnector: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Output') :param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') """ param = Conversions.enum_scalar_to_str(trigger_output_level, enums.LowHigh) outputConnector_cmd_val = self._cmd_group.get_repcap_cmd_value(outputConnector, repcap.OutputConnector) triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort) self._core.io.write(f'OUTPut{outputConnector_cmd_val}:TRIGger{triggerPort_cmd_val}:LEVel {param}')
# noinspection PyTypeChecker
[docs] def get(self, outputConnector=repcap.OutputConnector.Default, triggerPort=repcap.TriggerPort.Default) -> enums.LowHigh: """SCPI: OUTPut<up>:TRIGger<tp>:LEVel \n Snippet: value: enums.LowHigh = driver.applications.k70Vsa.output.trigger.level.get(outputConnector = repcap.OutputConnector.Default, triggerPort = repcap.TriggerPort.Default) \n Defines the level of the (TTL compatible) signal generated at the trigger output. Works only if you have selected a user-defined output with method RsFsw.Applications.K17_Mcgd.Output.Trigger.Otype.set. \n :param outputConnector: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Output') :param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') :return: trigger_output_level: No help available""" outputConnector_cmd_val = self._cmd_group.get_repcap_cmd_value(outputConnector, repcap.OutputConnector) triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort) response = self._core.io.query_str(f'OUTPut{outputConnector_cmd_val}:TRIGger{triggerPort_cmd_val}:LEVel?') return Conversions.str_to_scalar_enum(response, enums.LowHigh)