Source code for RsFsw.Implementations.Applications.K70_Vsa.Calculate.Trace.Value

from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import enums
from ...... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class ValueCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("value", core, parent)

[docs] def set(self, trace_ref_type: enums.TraceRefType, window=repcap.Window.Default, trace=repcap.Trace.Default) -> None: """ ``CALCulate<n>:TRACe<t>[:VALue]`` \n Snippet: ``driver.applications.k70Vsa.calculate.trace.value.set(trace_ref_type = enums.TraceRefType.ERRor, window = repcap.Window.Default, trace = repcap.Trace.Default)`` \n This commands selects the signal to be used as the data source for a trace. For method ``RsFsw.display.window.subwindow.trace.mode.set()`` View, the data source to be evaluated cannot be changed. It remains set to the value that was most recently set. :param trace_ref_type: MEAS | REF | ERRor | TCAP MEAS Measurement signal REF Reference signal ERR Error TCAP Capture buffer :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') """ param = Conversions.enum_scalar_to_str(trace_ref_type, enums.TraceRefType) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace) self._core.io.write(f'CALCulate{window_cmd_val}:TRACe{trace_cmd_val}:VALue {param}')
# noinspection PyTypeChecker
[docs] def get(self, window=repcap.Window.Default, trace=repcap.Trace.Default) -> enums.TraceRefType: """ ``CALCulate<n>:TRACe<t>[:VALue]`` \n Snippet: ``value: enums.TraceRefType = driver.applications.k70Vsa.calculate.trace.value.get(window = repcap.Window.Default, trace = repcap.Trace.Default)`` \n This commands selects the signal to be used as the data source for a trace. For method ``RsFsw.display.window.subwindow.trace.mode.set()`` View, the data source to be evaluated cannot be changed. It remains set to the value that was most recently set. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') :return: trace_ref_type: MEAS | REF | ERRor | TCAP MEAS Measurement signal REF Reference signal ERR Error TCAP Capture buffer """ window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace) response = self._core.io.query_str(f'CALCulate{window_cmd_val}:TRACe{trace_cmd_val}:VALue?') return Conversions.str_to_scalar_enum(response, enums.TraceRefType)