from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import enums
from ...... import repcap
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class OtypeCls:
"""Otype commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("otype", core, parent)
[docs] def set(self, output_type: enums.TriggerOutType, triggerPort=repcap.TriggerPort.Default) -> None:
"""SCPI: OUTPut:TRIGger<tp>:OTYPe \n
Snippet: driver.applications.k60Transient.output.trigger.otype.set(output_type = enums.TriggerOutType.DEVice, triggerPort = repcap.TriggerPort.Default) \n
Selects the type of signal generated at the trigger output. \n
:param output_type: DEVice Sends a trigger signal when the FSW has triggered internally. TARMed Sends a trigger signal when the trigger is armed and ready for an external trigger event. UDEFined Sends a user-defined trigger signal. For more information, see method RsFsw.Applications.K10x_Lte.Output.Trigger.Level.set.
:param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger')
"""
param = Conversions.enum_scalar_to_str(output_type, enums.TriggerOutType)
triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort)
self._core.io.write(f'OUTPut:TRIGger{triggerPort_cmd_val}:OTYPe {param}')
# noinspection PyTypeChecker
[docs] def get(self, triggerPort=repcap.TriggerPort.Default) -> enums.TriggerOutType:
"""SCPI: OUTPut:TRIGger<tp>:OTYPe \n
Snippet: value: enums.TriggerOutType = driver.applications.k60Transient.output.trigger.otype.get(triggerPort = repcap.TriggerPort.Default) \n
Selects the type of signal generated at the trigger output. \n
:param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger')
:return: output_type: DEVice Sends a trigger signal when the FSW has triggered internally. TARMed Sends a trigger signal when the trigger is armed and ready for an external trigger event. UDEFined Sends a user-defined trigger signal. For more information, see method RsFsw.Applications.K10x_Lte.Output.Trigger.Level.set."""
triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort)
response = self._core.io.query_str(f'OUTPut:TRIGger{triggerPort_cmd_val}:OTYPe?')
return Conversions.str_to_scalar_enum(response, enums.TriggerOutType)