from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import repcap
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class StopCls:
"""Stop commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("stop", core, parent)
[docs] def set(self, stop_frequency: float, window=repcap.Window.Default, trace=repcap.Trace.Default) -> None:
"""SCPI: DISPlay[:WINDow<n>]:TRACe<t>:X[:SCALe]:STOP \n
Snippet: driver.applications.k40PhaseNoise.display.window.trace.x.scale.stop.set(stop_frequency = 1.0, window = repcap.Window.Default, trace = repcap.Trace.Default) \n
Selects the stop frequency of the display range. Before you can use the command you have to select a manual display range
for the x-axis with method RsFsw.Applications.K40_PhaseNoise.Display.Window.Trace.X.Scale.Scope.set. \n
:param stop_frequency: Stop offset frequency of a half decade. Note that the stop offset you want to display has to be part of the current measurement range. Range: 300 mHz to 10 GHz, Unit: HZ
:param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window')
:param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace')
"""
param = Conversions.decimal_value_to_str(stop_frequency)
window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window)
trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace)
self._core.io.write(f'DISPlay:WINDow{window_cmd_val}:TRACe{trace_cmd_val}:X:SCALe:STOP {param}')
[docs] def get(self, window=repcap.Window.Default, trace=repcap.Trace.Default) -> float:
"""SCPI: DISPlay[:WINDow<n>]:TRACe<t>:X[:SCALe]:STOP \n
Snippet: value: float = driver.applications.k40PhaseNoise.display.window.trace.x.scale.stop.get(window = repcap.Window.Default, trace = repcap.Trace.Default) \n
Selects the stop frequency of the display range. Before you can use the command you have to select a manual display range
for the x-axis with method RsFsw.Applications.K40_PhaseNoise.Display.Window.Trace.X.Scale.Scope.set. \n
:param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window')
:param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace')
:return: stop_frequency: Stop offset frequency of a half decade. Note that the stop offset you want to display has to be part of the current measurement range. Range: 300 mHz to 10 GHz, Unit: HZ"""
window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window)
trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace)
response = self._core.io.query_str(f'DISPlay:WINDow{window_cmd_val}:TRACe{trace_cmd_val}:X:SCALe:STOP?')
return Conversions.str_to_float(response)