Source code for RsFsw.Implementations.Applications.K40_PhaseNoise.Display.Window.Trace.X.Scale.Start

from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class StartCls: """Start commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("start", core, parent)
[docs] def set(self, start_frequency: float, window=repcap.Window.Default, trace=repcap.Trace.Default) -> None: """SCPI: DISPlay[:WINDow<n>]:TRACe<t>:X[:SCALe]:STARt \n Snippet: driver.applications.k40PhaseNoise.display.window.trace.x.scale.start.set(start_frequency = 1.0, window = repcap.Window.Default, trace = repcap.Trace.Default) \n Selects the start frequency of the display range. Before you can use the command you have to select a manual display range for the x-axis with method RsFsw.Applications.K40_PhaseNoise.Display.Window.Trace.X.Scale.Scope.set. \n :param start_frequency: Start offset frequency of a half decade. Note that the start offset you want to display has to be part of the current measurement range. Range: 100 mHz to 3 GHz, Unit: HZ :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') """ param = Conversions.decimal_value_to_str(start_frequency) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace) self._core.io.write(f'DISPlay:WINDow{window_cmd_val}:TRACe{trace_cmd_val}:X:SCALe:STARt {param}')
[docs] def get(self, window=repcap.Window.Default, trace=repcap.Trace.Default) -> float: """SCPI: DISPlay[:WINDow<n>]:TRACe<t>:X[:SCALe]:STARt \n Snippet: value: float = driver.applications.k40PhaseNoise.display.window.trace.x.scale.start.get(window = repcap.Window.Default, trace = repcap.Trace.Default) \n Selects the start frequency of the display range. Before you can use the command you have to select a manual display range for the x-axis with method RsFsw.Applications.K40_PhaseNoise.Display.Window.Trace.X.Scale.Scope.set. \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') :return: start_frequency: Start offset frequency of a half decade. Note that the start offset you want to display has to be part of the current measurement range. Range: 100 mHz to 3 GHz, Unit: HZ""" window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace) response = self._core.io.query_str(f'DISPlay:WINDow{window_cmd_val}:TRACe{trace_cmd_val}:X:SCALe:STARt?') return Conversions.str_to_float(response)