Source code for RsFsw.Implementations.Applications.K14x_Nr5G.Output.Trigger.Pulse.Immediate

from .......Internal.Core import Core
from .......Internal.CommandsGroup import CommandsGroup
from ....... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class ImmediateCls: """Immediate commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("immediate", core, parent)
[docs] def set(self, outputConnector=repcap.OutputConnector.Default, triggerPort=repcap.TriggerPort.Default) -> None: """SCPI: OUTPut<up>:TRIGger<tp>:PULSe:IMMediate \n Snippet: driver.applications.k14Xnr5G.output.trigger.pulse.immediate.set(outputConnector = repcap.OutputConnector.Default, triggerPort = repcap.TriggerPort.Default) \n Sends a trigger signal from the analyzer to the DUT. For combined measurement, this command is useful to start a closed-loop trigger sequence. \n :param outputConnector: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Output') :param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') """ outputConnector_cmd_val = self._cmd_group.get_repcap_cmd_value(outputConnector, repcap.OutputConnector) triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort) self._core.io.write(f'OUTPut{outputConnector_cmd_val}:TRIGger{triggerPort_cmd_val}:PULSe:IMMediate')
[docs] def set_with_opc(self, outputConnector=repcap.OutputConnector.Default, triggerPort=repcap.TriggerPort.Default, opc_timeout_ms: int = -1) -> None: outputConnector_cmd_val = self._cmd_group.get_repcap_cmd_value(outputConnector, repcap.OutputConnector) triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort) """SCPI: OUTPut<up>:TRIGger<tp>:PULSe:IMMediate \n Snippet: driver.applications.k14Xnr5G.output.trigger.pulse.immediate.set_with_opc(outputConnector = repcap.OutputConnector.Default, triggerPort = repcap.TriggerPort.Default) \n Sends a trigger signal from the analyzer to the DUT. For combined measurement, this command is useful to start a closed-loop trigger sequence. \n Same as set, but waits for the operation to complete before continuing further. Use the RsFsw.utilities.opc_timeout_set() to set the timeout value. \n :param outputConnector: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Output') :param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') :param opc_timeout_ms: Maximum time to wait in milliseconds, valid only for this call.""" self._core.io.write_with_opc(f'OUTPut{outputConnector_cmd_val}:TRIGger{triggerPort_cmd_val}:PULSe:IMMediate', opc_timeout_ms)