from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import enums
from ...... import repcap
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class UnitCls:
"""Unit commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("unit", core, parent)
[docs] def set(self, unit: enums.LimitUnitB, window=repcap.Window.Default, limitIx=repcap.LimitIx.Default) -> None:
"""SCPI: CALCulate<n>:LIMit<li>:UNIT \n
Snippet: driver.applications.k14Xnr5G.calculate.limit.unit.set(unit = enums.LimitUnitB.AMPere, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default) \n
Defines the unit of a limit line. \n
:param unit: DBM | DBPW | WATT | DBUV | DBMV | VOLT | DBUA | AMPere | DB | DBUV_M | DBUA_M | DBM_hz | DBM_mhz | DBUV_mhz | DBMV_mhz | DBUa_mhz | DBUV_m | DBUa_m | DBUV_mmhz | DBUa_mmhz | DBPW_mhz | DBPT_mhz | DBPT | (unitless) If you select a dB-based unit for the limit line, the command automatically turns the limit line into a relative limit line.
:param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate')
:param limitIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Limit')
"""
param = Conversions.enum_scalar_to_str(unit, enums.LimitUnitB)
window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window)
limitIx_cmd_val = self._cmd_group.get_repcap_cmd_value(limitIx, repcap.LimitIx)
self._core.io.write(f'CALCulate{window_cmd_val}:LIMit{limitIx_cmd_val}:UNIT {param}')
# noinspection PyTypeChecker
[docs] def get(self, window=repcap.Window.Default, limitIx=repcap.LimitIx.Default) -> enums.LimitUnitB:
"""SCPI: CALCulate<n>:LIMit<li>:UNIT \n
Snippet: value: enums.LimitUnitB = driver.applications.k14Xnr5G.calculate.limit.unit.get(window = repcap.Window.Default, limitIx = repcap.LimitIx.Default) \n
Defines the unit of a limit line. \n
:param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate')
:param limitIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Limit')
:return: unit: DBM | DBPW | WATT | DBUV | DBMV | VOLT | DBUA | AMPere | DB | DBUV_M | DBUA_M | DBM_hz | DBM_mhz | DBUV_mhz | DBMV_mhz | DBUa_mhz | DBUV_m | DBUa_m | DBUV_mmhz | DBUa_mmhz | DBPW_mhz | DBPT_mhz | DBPT | (unitless) If you select a dB-based unit for the limit line, the command automatically turns the limit line into a relative limit line."""
window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window)
limitIx_cmd_val = self._cmd_group.get_repcap_cmd_value(limitIx, repcap.LimitIx)
response = self._core.io.query_str(f'CALCulate{window_cmd_val}:LIMit{limitIx_cmd_val}:UNIT?')
return Conversions.str_to_scalar_enum(response, enums.LimitUnitB)