Source code for RsFsw.Implementations.Applications.K14x_Nr5G.Calculate.Limit.AcPower.Pmode

from .......Internal.Core import Core
from .......Internal.CommandsGroup import CommandsGroup
from .......Internal import Conversions
from ....... import enums
from ....... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class PmodeCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("pmode", core, parent)

[docs] def set(self, mode: enums.LogicalFnc, window=repcap.Window.Default, limitIx=repcap.LimitIx.Default) -> None: """ ``CALCulate<n>:LIMit<li>:ACPower:PMODe`` \n Snippet: ``driver.applications.k14Xnr5G.calculate.limit.acPower.pmode.set(mode = enums.LogicalFnc.AND, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default)`` \n Selects the limit evaluation mode for ACLR measurements. Supported for ACLR measurements in the LTE and 5G applications. :param mode: AND Overall limit check passes if both absolute and relative limit checks pass. OR Overall limit check passes if either absolute or relative limit checks pass. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param limitIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Limit') """ param = Conversions.enum_scalar_to_str(mode, enums.LogicalFnc) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) limitIx_cmd_val = self._cmd_group.get_repcap_cmd_value(limitIx, repcap.LimitIx) self._core.io.write(f'CALCulate{window_cmd_val}:LIMit{limitIx_cmd_val}:ACPower:PMODe {param}')
# noinspection PyTypeChecker
[docs] def get(self, window=repcap.Window.Default, limitIx=repcap.LimitIx.Default) -> enums.LogicalFnc: """ ``CALCulate<n>:LIMit<li>:ACPower:PMODe`` \n Snippet: ``value: enums.LogicalFnc = driver.applications.k14Xnr5G.calculate.limit.acPower.pmode.get(window = repcap.Window.Default, limitIx = repcap.LimitIx.Default)`` \n Selects the limit evaluation mode for ACLR measurements. Supported for ACLR measurements in the LTE and 5G applications. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param limitIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Limit') :return: mode: AND Overall limit check passes if both absolute and relative limit checks pass. OR Overall limit check passes if either absolute or relative limit checks pass. """ window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) limitIx_cmd_val = self._cmd_group.get_repcap_cmd_value(limitIx, repcap.LimitIx) response = self._core.io.query_str(f'CALCulate{window_cmd_val}:LIMit{limitIx_cmd_val}:ACPower:PMODe?') return Conversions.str_to_scalar_enum(response, enums.LogicalFnc)