[docs]classYCls:"""Y commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""def__init__(self,core:Core,parent):self._core=coreself._cmd_group=CommandsGroup("y",core,parent)
[docs]defset(self,result:float,window=repcap.Window.Default,marker=repcap.Marker.Default)->None:"""SCPI: CALCulate<n>:MARKer<m>:Y \n Snippet: driver.applications.k10Xlte.calculate.marker.y.set(result = 1.0, window = repcap.Window.Default, marker = repcap.Marker.Default) \n Queries the position of a marker on the y-axis. In result displays with a third aspect (for example 'EVM vs Symbol x Carrier') , you can also use the command to define the position of the marker on the y-axis. If necessary, the command activates the marker first. To get a valid result, you have to perform a complete measurement with synchronization to the end of the measurement before reading out the result. This is only possible for single measurement mode. See also method RsFsw.Applications.K10x_Lte.Initiate.Continuous.set. \n :param result: numeric value Result at the marker position. The type of value and its unit depend on the selected result display. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param marker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Marker') """param=Conversions.decimal_value_to_str(result)window_cmd_val=self._cmd_group.get_repcap_cmd_value(window,repcap.Window)marker_cmd_val=self._cmd_group.get_repcap_cmd_value(marker,repcap.Marker)self._core.io.write(f'CALCulate{window_cmd_val}:MARKer{marker_cmd_val}:Y {param}')
[docs]defget(self,window=repcap.Window.Default,marker=repcap.Marker.Default)->float:"""SCPI: CALCulate<n>:MARKer<m>:Y \n Snippet: value: float = driver.applications.k10Xlte.calculate.marker.y.get(window = repcap.Window.Default, marker = repcap.Marker.Default) \n Queries the position of a marker on the y-axis. In result displays with a third aspect (for example 'EVM vs Symbol x Carrier') , you can also use the command to define the position of the marker on the y-axis. If necessary, the command activates the marker first. To get a valid result, you have to perform a complete measurement with synchronization to the end of the measurement before reading out the result. This is only possible for single measurement mode. See also method RsFsw.Applications.K10x_Lte.Initiate.Continuous.set. \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param marker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Marker') :return: result: numeric value Result at the marker position. The type of value and its unit depend on the selected result display."""window_cmd_val=self._cmd_group.get_repcap_cmd_value(window,repcap.Window)marker_cmd_val=self._cmd_group.get_repcap_cmd_value(marker,repcap.Marker)response=self._core.io.query_str(f'CALCulate{window_cmd_val}:MARKer{marker_cmd_val}:Y?')returnConversions.str_to_float(response)