Source code for RsFsw.Implementations.Applications.K10x_Lte.Calculate.DeltaMarker.Function.Fixed.Rpoint.X

from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class XCls: """X commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("x", core, parent)
[docs] def set(self, ref_point: float, window=repcap.Window.Default, deltaMarker=repcap.DeltaMarker.Default) -> None: """SCPI: CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X \n Snippet: driver.applications.k10Xlte.calculate.deltaMarker.function.fixed.rpoint.x.set(ref_point = 1.0, window = repcap.Window.Default, deltaMarker = repcap.DeltaMarker.Default) \n Defines the horizontal position of the fixed delta marker reference point. The coordinates of the reference may be anywhere in the diagram. \n :param ref_point: Numeric value that defines the horizontal position of the reference. For frequency domain measurements, it is a frequency in Hz. For time domain measurements, it is a point in time in s. Unit: HZ :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param deltaMarker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'DeltaMarker') """ param = Conversions.decimal_value_to_str(ref_point) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) deltaMarker_cmd_val = self._cmd_group.get_repcap_cmd_value(deltaMarker, repcap.DeltaMarker) self._core.io.write(f'CALCulate{window_cmd_val}:DELTamarker{deltaMarker_cmd_val}:FUNCtion:FIXed:RPOint:X {param}')
[docs] def get(self, window=repcap.Window.Default, deltaMarker=repcap.DeltaMarker.Default) -> float: """SCPI: CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X \n Snippet: value: float = driver.applications.k10Xlte.calculate.deltaMarker.function.fixed.rpoint.x.get(window = repcap.Window.Default, deltaMarker = repcap.DeltaMarker.Default) \n Defines the horizontal position of the fixed delta marker reference point. The coordinates of the reference may be anywhere in the diagram. \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Calculate') :param deltaMarker: optional repeated capability selector. Default value: Nr1 (settable in the interface 'DeltaMarker') :return: ref_point: Numeric value that defines the horizontal position of the reference. For frequency domain measurements, it is a frequency in Hz. For time domain measurements, it is a point in time in s. Unit: HZ""" window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) deltaMarker_cmd_val = self._cmd_group.get_repcap_cmd_value(deltaMarker, repcap.DeltaMarker) response = self._core.io.query_str(f'CALCulate{window_cmd_val}:DELTamarker{deltaMarker_cmd_val}:FUNCtion:FIXed:RPOint:X?') return Conversions.str_to_float(response)