Minimum
SCPI Command :
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
- class MinimumCls[source]
Minimum commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(window=Window.Default, limitIx=LimitIx.Default, subBlock=SubBlock.Default, powerClass=PowerClass.Default) float [source]
# SCPI: CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum value: float = driver.calculate.limit.espectrum.pclass.minimum.get(window = repcap.Window.Default, limitIx = repcap.LimitIx.Default, subBlock = repcap.SubBlock.Default, powerClass = repcap.PowerClass.Default)
- Defines the lower limit of a particular power class.
INTRO_CMD_HELP: Note:
The first power class always has a lower limit of -200 dBm.
The lower limit of a power class must always be the same as the upper limit of the previous power class.
The power class must already exist (see method RsFsw.Calculate.Limit.Espectrum.Pclass.Count.set) .
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- param limitIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)
- param subBlock
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)
- param powerClass
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pclass’)
- return
level: Range: -200 dBm to 199.9 dBm, Unit: dBm
- set(level: float, window=Window.Default, limitIx=LimitIx.Default, subBlock=SubBlock.Default, powerClass=PowerClass.Default) None [source]
# SCPI: CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum driver.calculate.limit.espectrum.pclass.minimum.set(level = 1.0, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default, subBlock = repcap.SubBlock.Default, powerClass = repcap.PowerClass.Default)
- Defines the lower limit of a particular power class.
INTRO_CMD_HELP: Note:
The first power class always has a lower limit of -200 dBm.
The lower limit of a power class must always be the same as the upper limit of the previous power class.
The power class must already exist (see method RsFsw.Calculate.Limit.Espectrum.Pclass.Count.set) .
- param level
Range: -200 dBm to 199.9 dBm, Unit: dBm
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- param limitIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)
- param subBlock
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)
- param powerClass