Minimum

SCPI Command :

CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(window=Window.Default, limitIx=LimitIx.Default, subBlock=SubBlock.Default, powerClass=PowerClass.Default) float[source]
# CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
value: float = driver.calculate.limit.espectrum.pclass.minimum.get(window = repcap.Window.Default, limitIx = repcap.LimitIx.Default, subBlock = repcap.SubBlock.Default, powerClass = repcap.PowerClass.Default)

Defines the lower limit of a particular power class. .. note:

- The first power class always has a lower limit of -200 dBm.
- The lower limit of a power class must always be the same as the upper limit of the previous power class.
- The power class must already exist (see method ``RsFsw.calculate.limit.espectrum.pclass.count.set()`` ) .
Parameters:
  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

  • limitIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)

  • subBlock – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)

  • powerClass – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pclass’)

Returns:

level: Range: -200 dBm to 199.9 dBm, Unit: dBm

set(level: float, window=Window.Default, limitIx=LimitIx.Default, subBlock=SubBlock.Default, powerClass=PowerClass.Default) None[source]
# CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
driver.calculate.limit.espectrum.pclass.minimum.set(level = 1.0, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default, subBlock = repcap.SubBlock.Default, powerClass = repcap.PowerClass.Default)

Defines the lower limit of a particular power class. .. note:

- The first power class always has a lower limit of -200 dBm.
- The lower limit of a power class must always be the same as the upper limit of the previous power class.
- The power class must already exist (see method ``RsFsw.calculate.limit.espectrum.pclass.count.set()`` ) .
Parameters:
  • level – Range: -200 dBm to 199.9 dBm, Unit: dBm

  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

  • limitIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)

  • subBlock – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)

  • powerClass – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pclass’)