Absolute

SCPI Command :

CALCulate<n>:LIMit<li>:ACPower:GAP<gap>:MANual:UPPer:ABSolute
class AbsoluteCls[source]

Absolute commands group definition. 2 total commands, 1 Subgroups, 1 group commands

get(sb_gaps: RsFsw.enums.SubBlockGaps, window=Window.Default, limitIx=LimitIx.Default, gapChannel=GapChannel.Default) float[source]
# SCPI: CALCulate<n>:LIMit<li>:ACPower:GAP<gap>:MANual:UPPer:ABSolute
value: float = driver.calculate.limit.acPower.gap.manual.upper.absolute.get(sb_gaps = enums.SubBlockGaps.AB, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default, gapChannel = repcap.GapChannel.Default)

Defines the absolute limit of the specified upper gap (CACLR) channel. If you define both an absolute limit and a relative limit, the FSW uses the lower value for the limit check. Is only available for for asymmetrical (manual) configuration of gap channels (see [SENSe:]POWer:ACHannel:GAP<gap>:MODE) .

param sb_gaps

AB | BC | CD | DE | EF | FG | GH Name of the gap, defined by the letters of the surrounding sub blocks (e.g. ‘AB’ for the gap between sub blocks A and B) .

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

param limitIx

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)

param gapChannel

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Gap’)

return

limit: Defines the absolute limit of the specified gap channel. Unit: dBm

set(sb_gaps: RsFsw.enums.SubBlockGaps, limit: float, window=Window.Default, limitIx=LimitIx.Default, gapChannel=GapChannel.Default) None[source]
# SCPI: CALCulate<n>:LIMit<li>:ACPower:GAP<gap>:MANual:UPPer:ABSolute
driver.calculate.limit.acPower.gap.manual.upper.absolute.set(sb_gaps = enums.SubBlockGaps.AB, limit = 1.0, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default, gapChannel = repcap.GapChannel.Default)

Defines the absolute limit of the specified upper gap (CACLR) channel. If you define both an absolute limit and a relative limit, the FSW uses the lower value for the limit check. Is only available for for asymmetrical (manual) configuration of gap channels (see [SENSe:]POWer:ACHannel:GAP<gap>:MODE) .

param sb_gaps

AB | BC | CD | DE | EF | FG | GH Name of the gap, defined by the letters of the surrounding sub blocks (e.g. ‘AB’ for the gap between sub blocks A and B) .

param limit

Defines the absolute limit of the specified gap channel. Unit: dBm

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

param limitIx

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)

param gapChannel

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Gap’)

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.calculate.limit.acPower.gap.manual.upper.absolute.clone()