External<ExternalPort>

SCPI Command :

TRIGger[:SEQuence]:LEVel[:EXTernal<port>]
Commands in total: 1
Subgroups: 0
Direct child commands: 1

Repeated Capability Setting:

# Range: Nr1 .. Nr3

driver.applications.k91Wlan.trigger.sequence.level.external.repcap_externalPort_set(repcap.ExternalPort.Nr1)
get(externalPort=ExternalPort.Default) float[source]
# TRIGger[:SEQuence]:LEVel[:EXTernal<port>]
value: float = driver.applications.k91Wlan.trigger.sequence.level.external.get(externalPort = repcap.ExternalPort.Default)

Defines the level the external signal must exceed to cause a trigger event. Note that the variable ‘Input/Output’ connectors (ports 2+3) must be set for use as input using the method RsFsw.applications.k17Mcgd.output.trigger.direction.set() command. For details on the trigger source see ‘Trigger Source’.

Parameters:

externalPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘External’)

Returns:

trigger_level: Range: 0.5 V to 3.5 V, Unit: V

set(trigger_level: float, externalPort=ExternalPort.Default) None[source]
# TRIGger[:SEQuence]:LEVel[:EXTernal<port>]
driver.applications.k91Wlan.trigger.sequence.level.external.set(trigger_level = 1.0, externalPort = repcap.ExternalPort.Default)

Defines the level the external signal must exceed to cause a trigger event. Note that the variable ‘Input/Output’ connectors (ports 2+3) must be set for use as input using the method RsFsw.applications.k17Mcgd.output.trigger.direction.set() command. For details on the trigger source see ‘Trigger Source’.

Parameters:
  • trigger_level – Range: 0.5 V to 3.5 V, Unit: V

  • externalPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘External’)

Cloning the Group

# Create a copy of the original group, that exists independently
external_copy = driver.applications.k91Wlan.trigger.sequence.level.external.clone()