Left
SCPI Command :
CALCulate<n>:MARKer<m>:X:SLIMits:LEFT
- class LeftCls[source]
Left commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(window=Window.Default, marker=Marker.Default) float [source]
# SCPI: CALCulate<n>:MARKer<m>:X:SLIMits:LEFT value: float = driver.applications.k91Wlan.calculate.marker.x.slimits.left.get(window = repcap.Window.Default, marker = repcap.Marker.Default)
Defines the left limit of the marker search range for all markers in all windows. If you perform a measurement in the time domain, this command limits the range of the trace to be analyzed.
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- param marker
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Marker’)
- return
search_limit: The value range depends on the frequency range or sweep time. The unit is Hz for frequency domain measurements and s for time domain measurements. Unit: HZ
- set(search_limit: float, window=Window.Default, marker=Marker.Default) None [source]
# SCPI: CALCulate<n>:MARKer<m>:X:SLIMits:LEFT driver.applications.k91Wlan.calculate.marker.x.slimits.left.set(search_limit = 1.0, window = repcap.Window.Default, marker = repcap.Marker.Default)
Defines the left limit of the marker search range for all markers in all windows. If you perform a measurement in the time domain, this command limits the range of the trace to be analyzed.
- param search_limit
The value range depends on the frequency range or sweep time. The unit is Hz for frequency domain measurements and s for time domain measurements. Unit: HZ
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- param marker
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Marker’)