Limit
SCPI Command :
CALCulate<n>:TABLe:PHASe:POINt:LIMit
- class LimitCls[source]
Limit commands group definition. 2 total commands, 1 Subgroups, 1 group commands
- class LimitStruct[source]
Response structure. Fields:
Lower_Limit: float: Lower limit of the valid value range. Unit: S
Upper_Limit: float: Upper limit of the valid value range. Unit: S
- get(window=Window.Default) LimitStruct [source]
# SCPI: CALCulate<n>:TABLe:PHASe:POINt:LIMit value: LimitStruct = driver.applications.k6Pulse.calculate.table.phase.point.limit.get(window = repcap.Window.Default)
Defines the valid value range for the limit check for the selected parameter if limit check is active (CALCulate<n>:TABLe:<ParameterGroup>:<Parameter>:LIMit:STATeON) . Commands for the parameter group <TSIDelobe> are only available if the additional option FSW-K6S is installed. For details on the individual parameters see ‘Pulse parameters’.
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- return
structure: for return value, see the help for LimitStruct structure arguments.
- set(lower_limit: float, upper_limit: float, window=Window.Default) None [source]
# SCPI: CALCulate<n>:TABLe:PHASe:POINt:LIMit driver.applications.k6Pulse.calculate.table.phase.point.limit.set(lower_limit = 1.0, upper_limit = 1.0, window = repcap.Window.Default)
Defines the valid value range for the limit check for the selected parameter if limit check is active (CALCulate<n>:TABLe:<ParameterGroup>:<Parameter>:LIMit:STATeON) . Commands for the parameter group <TSIDelobe> are only available if the additional option FSW-K6S is installed. For details on the individual parameters see ‘Pulse parameters’.
- param lower_limit
Lower limit of the valid value range. Unit: S
- param upper_limit
Upper limit of the valid value range. Unit: S
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.applications.k6Pulse.calculate.table.phase.point.limit.clone()
Subgroups