Level

SCPI Command :

OUTPut:TRIGger<tp>[:UDEFined]:LEVel
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(triggerPort=TriggerPort.Default) LowHigh[source]
# OUTPut:TRIGger<tp>[:UDEFined]:LEVel
value: enums.LowHigh = driver.applications.k60Transient.output.trigger.userDefined.level.get(triggerPort = repcap.TriggerPort.Default)

Defines the level of the (TTL compatible) signal generated at the trigger output. Works only if you have selected a user-defined output with method RsFsw.applications.k17Mcgd.output.trigger.otype.set() .

Parameters:

triggerPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

Returns:

level: HIGH 5 V LOW 0 V

set(level: LowHigh, triggerPort=TriggerPort.Default) None[source]
# OUTPut:TRIGger<tp>[:UDEFined]:LEVel
driver.applications.k60Transient.output.trigger.userDefined.level.set(level = enums.LowHigh.HIGH, triggerPort = repcap.TriggerPort.Default)

Defines the level of the (TTL compatible) signal generated at the trigger output. Works only if you have selected a user-defined output with method RsFsw.applications.k17Mcgd.output.trigger.otype.set() .

Parameters:
  • level – HIGH 5 V LOW 0 V

  • triggerPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)