FmSettling
SCPI Command :
CALCulate<n>:DISTribution:HOP:FMSettling
- Commands in total: 1Subgroups: 0Direct child commands: 1
- set(xaxis: AxisFmSettling, yaxis: YaXisItems, window=Window.Default) None[source]
# CALCulate<n>:DISTribution:HOP:FMSettling driver.applications.k60Transient.calculate.distribution.hop.fmSettling.set(xaxis = enums.AxisFmSettling.FMSLength, yaxis = enums.YaXisItems.COUNt, window = repcap.Window.Default)
Configures the Parameter Distribution result display for hop FM settling parameters.
- Parameters:
xaxis – FMSLength | FMSPoint | FMSTime FMSPoint FM settling point FMSTime FM settling time FMSLength FM settled length
yaxis – COUNt | OCCurrence Parameter to be displayed on the y-axis. COUNt Number of hops in which the parameter value occurred. OCCurance Percentage of all measured hops in which the parameter value occurred.
window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)