Level#
SCPI Command :
- OUTPut:TRIGger<tp>[:UDEFined]:LEVel
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get ( triggerPort=TriggerPort.Default ) LowHigh
- set ( level: LowHigh, triggerPort=TriggerPort.Default ) None
# OUTPut:TRIGger<tp>[:UDEFined]:LEVel # get: value: enums.LowHigh = driver.applications.k17Mcgd.output.trigger.userDefined.level.get(triggerPort = repcap.TriggerPort.Default) # set: driver.applications.k17Mcgd.output.trigger.userDefined.level.set(level = enums.LowHigh.HIGH, triggerPort = repcap.TriggerPort.Default)
Defines the level of the (TTL compatible) signal generated at the trigger output. Works only if you have selected a user-defined output with method
RsFsw.applications.k17Mcgd.output.trigger.otype.set().- Parameters:
level –
HIGH: 5 V
LOW: 0 V
triggerPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)