RfPower

SCPI Command :

TRIGger[:SEQuence]:LEVel:RFPower
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get() float[source]
# TRIGger[:SEQuence]:LEVel:RFPower
value: float = driver.applications.k14Xnr5G.trigger.sequence.level.rfPower.get()

Defines the power level the RF input must exceed to cause a trigger event. Note that any RF attenuation or preamplification is considered when the trigger level is analyzed. If defined, a reference level offset is also considered. The input signal must be between 500 MHz and 8 GHz.

set(level: float) None[source]
# TRIGger[:SEQuence]:LEVel:RFPower
driver.applications.k14Xnr5G.trigger.sequence.level.rfPower.set(level = 1.0)

Defines the power level the RF input must exceed to cause a trigger event. Note that any RF attenuation or preamplification is considered when the trigger level is analyzed. If defined, a reference level offset is also considered. The input signal must be between 500 MHz and 8 GHz.

Parameters:

level – For details on available trigger levels and trigger bandwidths, see the specifications document. Unit: DBM