AttRatio
SCPI Command :
[SENSe]:PROBe<p>:SETup:ATTRatio
- class AttRatioCls[source]
AttRatio commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(probe=Probe.Default) float [source]
# SCPI: [SENSe]:PROBe<p>:SETup:ATTRatio value: float = driver.applications.k14Xnr5G.sense.probe.setup.attRatio.get(probe = repcap.Probe.Default)
Defines the attenuation applied to the input at the probe. This setting is only available for modular probes.
- param probe
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Probe’)
- return
attenuation_ratio: 10 Attenuation by 20 dB (ratio= 10:1) 2 Attenuation by 6 dB (ratio= 2:1) Unit: DB
- set(attenuation_ratio: float, probe=Probe.Default) None [source]
# SCPI: [SENSe]:PROBe<p>:SETup:ATTRatio driver.applications.k14Xnr5G.sense.probe.setup.attRatio.set(attenuation_ratio = 1.0, probe = repcap.Probe.Default)
Defines the attenuation applied to the input at the probe. This setting is only available for modular probes.
- param attenuation_ratio
10 Attenuation by 20 dB (ratio= 10:1) 2 Attenuation by 6 dB (ratio= 2:1) Unit: DB
- param probe
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Probe’)