Direction
SCPI Command :
OUTPut<up>:TRIGger<tp>:DIRection
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(outputConnector=OutputConnector.Default, triggerPort=TriggerPort.Default) InOutDirection[source]
# OUTPut<up>:TRIGger<tp>:DIRection value: enums.InOutDirection = driver.applications.k14Xnr5G.output.trigger.direction.get(outputConnector = repcap.OutputConnector.Default, triggerPort = repcap.TriggerPort.Default)
Selects the trigger direction for trigger ports that serve as an input as well as an output.
- Parameters:
outputConnector – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Output’)
triggerPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
- Returns:
direction: INPut | OUTPut INPut Port works as an input. OUTPut Port works as an output.
- set(direction: InOutDirection, outputConnector=OutputConnector.Default, triggerPort=TriggerPort.Default) None[source]
# OUTPut<up>:TRIGger<tp>:DIRection driver.applications.k14Xnr5G.output.trigger.direction.set(direction = enums.InOutDirection.INPut, outputConnector = repcap.OutputConnector.Default, triggerPort = repcap.TriggerPort.Default)
Selects the trigger direction for trigger ports that serve as an input as well as an output.
- Parameters:
direction – INPut | OUTPut INPut Port works as an input. OUTPut Port works as an output.
outputConnector – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Output’)
triggerPort – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)