Result

SCPI Command :

CALCulate<n>:LIMit<li>:ACPower:ACHannel:RESult
Commands in total: 3
Subgroups: 2
Direct child commands: 1
get(result: AcpResult = None, window=Window.Default, limitIx=LimitIx.Default) str[source]
# CALCulate<n>:LIMit<li>:ACPower:ACHannel:RESult
value: str = driver.applications.k10Xlte.calculate.limit.acPower.achannel.result.get(result = enums.AcpResult.ABSolute, window = repcap.Window.Default, limitIx = repcap.LimitIx.Default)

Queries the state of the limit check for the adjacent channels in an ACLR measurement. To get a valid result, you have to perform a complete measurement with synchronization to the end of the measurement before reading out the result. This is only possible for single sweep mode. See also method RsFsw.applications.k10Xlte.initiate.continuous.set() .

Parameters:
  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

  • limitIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)

Cloning the Group

# Create a copy of the original group, that exists independently
result_copy = driver.applications.k10Xlte.calculate.limit.acPower.achannel.result.clone()

Subgroups